Seawater Service Solenoid Operated Deluge Valve

Product Advantages

  • Fast Acting Solenoid Control
  • Reliable Drip Tight Shut-off
  • Simple Design, Proven Reliable
  • Easy Installation & Maintenance

The Cla-Val Model 134-60 Seawater Service Solenoid Control Valve is an on-off control valve which either opens or closes upon receiving an electrical signal to the solenoid pilot control. This valve consists of UL Listed 100GS/2100GS Hytrol Main Valve, a three-way solenoid valve and an auxiliary pilot valve. This pilot control system alternately applies pressure to/or relieves pressure from the diaphragm chamber of the main valve. It is furnished either normally open (de-energize solenoid to open) or normally closed (energized solenoid to open).

Please note that the UL Listing applies to the 100G/2100G Hytrol Main Valve only.

Item Description
1.  100GS/2100GS UL Listed Hytrol Main Valve
2.  CS3S Solenoid Control
3.  100-01 Auxiliary Hytrol
4.  X58C Restriction Assembly
5.  CK2 Two-Way Manual Release Valve

Schematic Diagram


Specification

SIZES
Globe: 3” – 12” flanged
Angle: 3” – 12” flanged

END DETAILS
Ductile Iron 150 ANSI B16.42 flanged
Cast Steel 150 ANSI B16.5 flanged

PRESSURE RATINGS
150 class, 250 psi maximum (Ductile Iron)
150 class, 285 psi maximum (Cast Steel)
300 class, 400 psi maximum

TEMPERATURE RANGE
Water: to 180˚ F. Max

Materials

Main valve body & cover
Ductile Iron ASTM A-536*
Cast Steel ASTM A216-WCB*
Naval Bronze ASTM B61
Nickel Aluminum Bronze ASTM B148 C95800
Super Duplex Stainless Steel ASTM A890 GR5A
Stainless Steel ASTM A743-CF-8M

Main valve trim:
Bronze / Monel

Tubing & Fittings
316 SST, Monel, or 2507 SDS

Pilot control system:
Cast Bronze ASTM B61
UL Listed 3” – 12”

Functional Data

Cover Capacity



Pilot System Specifications

Temperature Range
Water: to 180˚F

Fluids
Air, water, light oils

Rubber Parts
Buna-N® Synthetic Rubber

Solenoid Control*
Body:
316 SS
Enclosure:
NEMA Type 1, 2, 3, 3S, 4, 4X general
purpose watertight
NEMA Type 6, 6P, 7, 9 watertight
Explosion Proof available at extra cost

Voltages:
110, 220 -50Hz AC
24, 120, 240, 480 -60Hz AC
6, 12, 24, 120, 240 – DC
Others available at extra cos

Max. operating pressure differential: 200 psi
Coil:
Insulation molded Class F
Watts AC 6
AC Volt Amps Inrush 30
AC Volt Amps Holding 16
Watts DC 10.6

Manual operator available at extra cost.

UL Listed: 3” – 12”
*Optional material available for Seawater Service

When Ordering,
Please Specify
1. Catalog No. 134-60
2. Valve Size
3. Pattern – Globe or Angle
4. Pressure Class
5. Threaded, Flanged or Grooved
6. Material Desired
7. Energized or De-energized to
Open Main Valve
8. Solenoid Enclosure, Voltage
& Hertz
9. When Vertically Installed