Pressure Reducing & Solenoid Shut-Off Valve

Product Advantages

  • Accurate Pressure Control
  • Wide Adjustment Ranges
  • Optional Check Feature Available
  • Quick Acting Solenoid Shut-Off
  • Easy Installation and Maintenance

The Cla-Val Model 93-01 Combination Pressure Reducing and Solenoid Shut-Off Valve consists of a Cla-Val Hytrol main valve, a reducing control and a solenoid control connected to the main valve. This valve automatically reduces higher inlet pressure to a steady lower downstream pressure, regardless of changing flow rate and/or varying inlet pressure.

The 93-01 is an accurate, pilot-operated regulator capable of holding downstream pressure to a pre-determined delivery pressure. When downstream pressure exceeds the pressure setting of the control pilot, the pilot valve and main valve close drip-tight. A solenoid control is provided to intercept the operation of the pressure reducing control and close the main valve. This valve is furnished either normally open (deenergized to open), or normally closed (energized to open). Pressure setting adjustment is made with a single adjusting screw.

Schematic Diagram
Item Description
1.  100-01 Hytrol Main Valve
2.  X58C Restriction Assembly
3.  CRD Pressure Reducing Control
4.  100-01 Hytrol (Reverse Flow)
5.  CS3 Solenoid Control

Optional Features
Item Description
A.  X46A Flow Clean Strainer
B.  CK2 Isolation Valve
C.  CV Flow Control (Closing)*
D.  Check Valves with Isolation Valve
H.  Solenoid Drain To Atmosphere
P.  X141 Pressure Gauge
S.  CV Speed Control (Opening)
V.  X101 Valve Position Indicator
Y.  X43 “Y” Strainer

*The closing speed control (optional) on this valve should
always be open at least three (3) turns off its seat.


Typical Applications

Electronic Control Service
A typical application for this valve is to reduce high transmission line pressures to lower distribution system levels, while opening and closing on command. The solenoid control feature can be activated by an electrical signal from a timer or programmer.

Fire Service
The Model 93-01 can be installed in a distribution line where there is a need to close the valve on the starting of a fire pump. The solenoid control is activated on pump start-up and closes the valve.


Model 93-01 (Uses 100-01 Hytrol Main Valve)

Pressure Ratings (Recommended Maximum Pressure – psi)

Materials

Model 93-01 Dimensions (In Inches)


Model 93-01 Metric Dimensions (Uses 100-01 Hytrol Main Valve)

Valve Options

X141 Pressure
Gauge

X101AR Valve
Position Indicator
with Air Release

X101
Valve Position
Indicator

X144 e-FlowMeter

X43H
Strainer

X43H
Strainer

Stainless
Steel Pilot

Model 93-01 Dimensions (In mm)



Pilot System Specifications

Adjustment Ranges
2 to 30 psi
15 to 75 psi
20 to 105 psi
30 to 300 psi*
*Supplied unless otherwise specified
Other ranges available, please consult factory

Temperature Range
Water: to 180°F

Fluids
Air, water, light oils

Materials
Standard Pilot System Materials
Pilot Control: Low Lead Bronze
Trim: Stainless Steel Type 303
Rubber: Buna-N® Synthetic Rubber

Optional Pilot System Materials
Pilot Systems are available with optional
Aluminum, Stainless Steel, Monel or
Cast Steel materials.
Note: Available with remote sensing control.

Solenoid Control

Body:
Brass ASTM B283

Enclosure:
NEMA Type 1,2,3,3S,4,4X general purpose
watertight*
NEMA Type 6,6P,7,9 Watertight Explosion
Proof available.

Voltages:
110, 220 -50Hz AC
24, 120, 240, 480 – 60Hz AC
6, 12, 24, 120, 240 – DC
Others available at additional cost

Max. operating pressure differential:
200 psi*

Coil:
Insulation molded Class F
Watts AC 6
AC Volt Amps Inrush 30
AC Volt Amps Holding 16
Watts DC 10.6
Manual operator available at additional
cost.

*Supplied unless otherwise specified
Note: Flowing Pressure Differential: 5 psi minimum

When Ordering, Specify:
1. Catalog No. 93-01
2. Valve Size
3. Pattern – Globe or Angle
4. Pressure Class
5. Threaded, Flanged or Grooved
6. Trim Material
7. Energized or de-energized to open
Main Valve
8. Solenoid Enclosure, Voltage &
Hertz, Coil Insulation, and Max.
Operating Pressure Differential
9. Desired Options
10. When Vertically Installed
11. Adjustment Range